RVK 60 P stair connection consists of outer and inner tube.
The outer tube is made from 100% recycled PE and made to fit on the outside of the inner tube.
The inner tube will slide inside the outer tube and be pushed out and in to the recess in the wall. The inner tube is pushed out/in mechanically. User-friendly "clips" to place reinforcing bars in the correct position.
Invisible Connections RVK 60 P is supplied in black steel or galvanized.
Capacity 57 kN, minimum landing thickness 170 mm at full capacity, 120 mm with reduced capacity.
For soundreduction combine with IC Box 100 SRU
Recommended maximum ULS load Fv,Ed [kN] | 57 kN |
Minimum landing thickness | 170 mm at full capacity, 120 mm with reduced capacity |
Weight black steel/galvanized version | 2,80 kg/2,85 kg |
Engineering / design
Memo no | Name/download | Format | |
---|---|---|---|
TSS/RVK V1.5 | Calculations tool, stair connections | Excel | |
Memo no 31 | Guidance, stair connections | ||
Memo no 41 | Additional products, stair connections | ||
Memo no 45 | Fire protection, stair connections | ||
Memo no 47 | Impact sound transmission, stair connections | ||
Memo no 54 | Technical specifications, stair connections | ||
Memo no 55 | Anchoring reinforcement, stair connections | ||
Memo no 64 | Anchoring reinforcement, units in pair, cc 250, stair connections | ||
Memo no 65 | Anchoring reinforcement, stair connections - TSS 20 FA | ||
Memo no 65 A | Anhoring reinforcement, stair connections - TSS 25 L |
Production / assembly
Memo no | Name/download | Format | |
---|---|---|---|
Memo TSS/RVK | Memo TSS RVK RECOMMENDED PRODUCTION | ||
Memo no 20 | RVK, Production procedure | ||
Memo no 32 | TSS, Production procedure. | ||
Memo no 66 | TSS 20 FA, assembling guidance. |
Seismic zones TSS - RVK
Memo no | Name/download | Format | |
---|---|---|---|
Calcyl, Earthquake. | Excel | ||
Des Bull | Des Bull Report. | ||
Analyses of stairwells performace and damage during Wenchuan earthquake. | |||
Memo no 70 | iC solution for earthquake and stairs. | ||
Memo no 71 | iC solution for earthquake and stairs spreadsheet. | ||
Memo no 72 | iC solution for earthquake and stairs additional reinforcement. |
Sustainability has more and more focus in the construction industry. So trying to make our products more sustainable and help the industry become greener is part of our strategy, and the idea for our new models. With the new models, we show that Invisible Connections takes sustainability seriously.
If we take the connection itself, then the outer tube is made of 100% recycled HDPE. When we replace the steel with a recycled HDPE, we reduce the steel consumption by 50%. Our new production line where these connections are produced is automated and we have thus reduced energy consumption.
We use renewable energy at our production facility. Choosing hydropower for our production facility is just one of several measures to reduce our environmental impact. The hydropower we use is produced locally, and provides a clean, flexible and reliable power supply.
Stairconnection Architects
Stairconnection Engineer
Stairconnection production
Stairconnection installation 1
Stairconnection installation 2
Stairconnection stairs in earthquake
Stairconnection earthquake installation
Brochuresfor downloading