Do you want more information and pricing?
BWC 55 light with stair connection TSS
- Products→
- Balcony connections→
- Balcony connection with shear(kN) force and simpel waterproofing→
- BWC 55 light with stair connection TSS
For column in front/slanted brace with simple waterproofing. Molded cover or hollow core
Capacity for horizontal load will depend on the chosen solution for transferring the power from TSS to BWC. By
need to transfer horizontal force, this detail must be worked out in each individual case, depending on
possibility of access.
See more in Invisible Connections® Memo 701b side 3
Max. shear force(kN) Tss 60p: | Tss 60p: 57kN |
Max. shearforce(kN) Tss 101/102p: | 100 kN |
Max. breaking load horizontal | Se egen tekst |
WC 55-light-1 outer tube | |
TSS (see drawing TSS stair connection) |
BWC 55 light
Memo nr | Navn / nedlastning | Format | |
---|---|---|---|
Memo nr 700 | BWC 55 740 BWC 55 LIGHT VEILEDNING | PFD | |
Memo nr 701b | BWC 55 light, tekniske spesifikasjoner | PFD | |
Memo nr 702b | BWC 55 light, beregning av forankringsarmering | PFD | |
Memo nr 703b | BWC 55 light, eksempel forankringsarmering | PFD | |
Memo nr 704 | BWC 55 740 og BWC 55 Light, eksempel | PFD | |
Memo nr 705 | BWC WB for isolerte veggelement | PFD |
Picture | Product | STP | DWG 2D | IFC | |
---|---|---|---|---|---|
BWC 55 light-1 | BWC 55 light-1 | BWC 55 light-1 | BWC 55 light-1 | BWC 55 light-1 | |
TSS 60 p | TSS 60 p | TSS 60 p | TSS 60 p | TSS 60 p | |
TSS 101 | TSS 101 | TSS 101 | TSS 101 | ||
TSS 102 | TSS 102 | TSS 102 | TSS 102 |
TSS 60 P consisting of an outer- and an inner tube.
The outer tube is made of 100% recycled PE and made to fit on the outside of the inner tube.
The inner tube will slide inside the outer tube and be pulled out and in to the recess in the wall. The inner tube is pulled out/in with a wire/return rope. The unit has a control line that indicate the correct position of the inner tube. As well as a hole for a locking bolt which ensures that the inner tube stays in the correct position. It also have user-friendly "clips" to place reinforcing bars in the correct position.
The TSS units are specially suitable where the elements are supplied with a finished surface from the factory, e.g. terrazzo.
Invisible Connections TSS 60 P is supplied in black steel or galvanized.
Capacity 57 kN, minimum landing thickness 170 mm at full capacity, 120 mm with reduced capacity.
For soundreduction combine with: IC Box 100 SRU
TSS 60 P can be used between stair and landing, see picture below.
RVK 60 P stair connection consists of outer and inner tube.
The outer tube is made from 100% recycled PE and made to fit on the outside of the inner tube.
The inner tube will slide inside the outer tube and be pushed out and in to the recess in the wall. The inner tube is pushed out/in mechanically. User-friendly "clips" to place reinforcing bars in the correct position.
Invisible Connections RVK 60 P is supplied in black steel or galvanized.
Capacity 57 kN, minimum landing thickness 170 mm at full capacity, 120 mm with reduced capacity.
For soundreduction combine with IC Box 100 SRU
TSS 101 stair connections consist of an outer tube and an inner tube. It contains of two hollow core sections, where the inner tube profile fits inside the outer tube. The inner tube will slide inside the outer tube and be pulled out and in to the recess in the wall. The inner tube is pulled out/in with a wire/return rope. The unit has a control line that indicate the correct position of the inner tube. As well as a hole for a locking bolt which ensures that the inner tube stays in the correct position.
The TSS units are specially suitable where the elements are supplied with a finished surface from the factory, e.g. terrazzo.
Invisible Connections TSS 101 is supplied in black steel or galvanized.
Capacity 100 kN, minimum landing thickness 200 mm at full capacity, 170 mm with reduced capacity.
For soundreduction combine with: IC Box 100 SRU
RVK101 stair connections consist of an outer tube and an inner tube. It contains of two hollow core sections, where the inner tube profile fits inside the outer tube. The inner tube will slide inside the outer tube and be pushed out and in to the recess in the wall. The inner tube is pushed out/in mechanically.
Invisible Connections TSS 101 is supplied in black steel or galvanized.
Capacity 100 kN, minimum landing thickness 200 mm at full capacity, 170 mm with reduced capacity.
For soundreduction combine with: IC Box 100 SRU
Balcony connection (shear) light installation
Balcony connection (shear) light production
Balcony connection (shear) light Engineer
Balcony connection (shear) light Architect
Brochuresfor downloading